Channels | 64 (common mode) |
Signals | Sinusoid, white noise, neural data, user defined |
Modes | Signal generation, short-to-ground |
Amplitude | 10mV, 20mV, 40mV pk-pk (user defined) |
Bandwidth | 0.01 Hz ~ 12kHz |
Resolution | 16 bit DAC @ 25kSps |
Noise | 1.5uV RMS, THD 0.3% (0.01Hz ~ 25kHz) |
Outputs | 2 x 34 pin Molex SSB6, 2 x Omnetics NSD-36, uFl |
Power | LiPo battery, 15 hr runtime between charges |
Dimensions | USB thumb-drive, 82 x 25 x 13 mm |
Software | hs-tester config (win32/64) |
Fits in the palm of your hand! Our low cost hs-tester is a precision arbitrary waveform generator that generates a variety of useful test signals for troubleshooting experiments. It enables rapid and automated testing of headstage functionality, channel gain and linearity, and input-referred noise measurement.
Ultra flexible, 1.1 ~ 1.6 mm O.D. headstage tether cables are available as regular cables or with our unique lightweight inline slip-ring commutator. Cable length made to order, up to 10 meters long, with or without magnets for easy plugging.
Adaptors
product ID | connector1 | connector2 | channels | length | width (mm) | |
---|---|---|---|---|---|---|
ADPT-NZA-DIP16 | DIP16 IC socket | Samtec MOLC | 16 | 27.9 | 15.9 | |
ADPT-NZA-SSB6 | 2 x Molex Slimstack SSB6 | Samtec MOLC | 64 | 52.7 | 13.4 | |
ADPT-OMN-SSB6 | 2 x Omnetics NSD36 | 2 x Molex Slimstack SSB6 | 64 | 14.7 | 13.0 | |
ADPT-ZIF33-SSB6 | Hirose FH-43B ZIF | 2 x Molex Slimstack SSB6 | 32 | 10.0 | 4.0 | |
ADPT-ZIF71-SSB6 | Hirose FH-43B ZIF | 2 x Molex Slimstack SSB6 | 64 | 15.9 | 11.0 | |
ADPT-NZA-OMN32 | 2 x Omnetics NSD36 | Samtec MOLC | 32 | 33.0 | 13.0 | |
ADPT-NZA-OMN64 | 2 x Omnetics NSD36 | 2 x Samtec MOLC | 64 | 51.5 | 13.3 | |
ADPT-SAM-OMN64 | 2 x Samtec FOLC | 2 x Omnetics NPD36 | 64 | 43.3 | 21.0 | |
ADPT-TET128 | 2 x Molex Slimstack SSB6 | 4 x Molex Slimstack SSB6 | 128 | 30.0 | 25.6 |
EIBs
product ID | probe interface | connector | channels | length | width (mm) | |
---|---|---|---|---|---|---|
EIB-TET32 | via array | Molex Slimstack SSB6 | 32 | 10.0 | 9.2 | |
EIB-TET64 | via array | 2 x Omnetics NPD | 64 | 21.3 | 21.3 | |
EIB-WIRE64 | via array | 2 x Molex Slimstack SSB6 | 64 | 10.0 | 10.3 | |
EIB-XBASE | single via | Panasonic P4S | 1 | 10.0 | 6.5 | |
EIB-LGA64 | flip chip array | 2 x Molex Slimstack SSB6 | 64 | 10.5 | 6.3 |
We have a range of adaptors suitable for all common probe interconnects. Custom probe adaptors upon request.
32 and 64 channel breakout boxes for easy interfacing with existing lab equipment.